Loading

SCT300

Code: SCT300
  • mineral insulated thermoelectric sensor
  • different types of sensor connections
  • accurate measurement and short reaction time to temperature changes
  • small dimensions enable working in hard-to-reach places
  • resistance to vibrations and the possibility of bending
  • sheath made of nickel alloy (Inconel 600)
Description

With sheathed thermocouples SCT300, the flexible part of the probe is a mineral insulated cable. This cable consists of a stainless steel outer sheath, in which the inner conductors are encased for insulation and compressed into a highly compacted ceramic mass. The outer sheath is made of stainless steel or Ni alloy. The inner conductors are welded together at the measuring end of the sheathed cable to form the thermocouple. In designs where the measuring element is not insulated the sheath is also welded to the thermocouple. Connector cables are connected to the other end of the sheathed Üable, the sheathed cable is hermetically sealed with a sealing compound. The connector wires form the basis for the electrical interface, with cable, a connector or a terminal block then attached to these connector wires.

Application areas:

  • general machinery and equipment design
  • measuring temperature of liquids, gases and solid bodies
  • all branches of industry
  • measurement laboratories

Specification
Measurement range
-40...+750°C (J)
-40...+1200°C (K, N)
Measuring element
TC J
TC K
TC N
Sheath
diameter 1,5...8 mm
any maximum length
nickel alloy 2.4816 (Inconel 600)
Accuracy
II class
I class
Operating temperature
max. 400°C
Files
Data sheet