Loading

CCA-Xci

Code: CCA-Xci
  • nominal pressure: 0...60 mbar up to 0...20 bar
  • accuracy: 0,1 % FSO
  • turn-down 1:5
  • two chamber aluminium die cast case or stainless field housing
  • internal or flush mounted capacitive ceramic sensor
  • HART®-communication
  • explosion protection: intrinsic safety (ia)
  • diaphragm ceramics Al2O3 (99.9 %)
  • optional features: explosion protection, flameproof equipment (d), integrated display and operating module, several process connections (thread, flange, DRD u.a.)
  • areas of application: mechanical and plant engineering, chemical industry, medical technology, food and beverage, environmental industry, packaging and paper industry
Description

The process pressure transmitter CCA-Xci measures the pressure of gases, steam, dust and fluids. The special-developed capacitive ceramic sensor for this transmitter has a high overpressure capability and excellent media stability.

Several process connections e.g. thread or flange are available. The transmitter is as a standard equipped with HART®-communication, the customer can choose between a two chamber aluminum die cast case or a stainless field housing.

Specification
Measurement range
0...60 mbar up to 0...20 bar
Output type
4...20 mA, 2-wire
HART
Process connection
G 1/2
G1 1/2
1/2 NPT
flange
Diaphragm
ceramics Al2O3 (99.9 %)
Power supply
12...28V DC
Accuracy
±0,1%
Display
LCD, 5 x 8 mm
LCD, 8 x 5 mm
Transmission protocol
HART®
Operating temperature
-20...+70°C
-40...+70°C
Medium temperature
-25...+125°C
Protection class
IP 67
Case material
stainless steel
aluminium