Loading

C3P1, C3P2

Code: C3P
  • canister load cell
  • capacity range: 500, 1K, 2K, 3K, 5K, 10K, 20K, 50K, and 100K lb (227, 454, 907, 1.4K, 2.27K, 4.54K, 9K, 13.6K, 22.7K and 45.4K kg)
  • environmentally sealed
  • operation temperature: -30° to +175°F
  • low delection
  • compact and rugged
  • FM approved
  • options: stainless steel design; CSA approval
Description

C3P1 and C3P2 cells are fabricated with high strength ‘ring’ type elements to provide an output signal of 3 mV/V at rated capacity. Each cell is designed for minimum deflection and 150% safe overload without damage.
C3P2 cells contain a second bridge. The second bridge can be used simultaneously with the irst bridge for dual output or be reserved as a backup in case of failure in the first bridge. Double diaphragm fabrication offers precision performance and long term reliability. Low deflection and superior sealing guarantee trouble-free operation. Relatively low mass and small delection under load, produce excellent frequency response. Overall, C3P1/C3P2 cells perform superbly in many environments where other transducers cannot.

APPLICATIONS:

  • test and measurement
  • calibration standards
  • redundant weighing systems

Specification
Rated load
227 kg
454 kg
907 kg
1400 kg
2270 kg
4540 kg
9000 kg
13600 kg
22700 kg
45400 kg
Combined error
± 0,1% RL
0,07% RL
Overload, safe
150% RL
Overload, ultimate
300% RL
Resistance
input: 350 ± 3,5 Ω
output: 350 ± 3,5 Ω
Rated output
3 mV/V
Sensor material
carbon steel
stainless steel
Protection class
IP 67
Operating temperature
-34,4...+79,4°C
Files
Data sheet
Process Weighing Technologies - Product Overview