Description
The 92 and 93 canisters are designed for compression applications. Its stainless steel construction combined with hermetically sealing allows the 92/93 to be used in demanding environments. Models differ from each other by rated output: model 92 has 2mV/V ±0.002 and model 93 has 3mV/V ±0.003.
Hermetic sealing offers excellent protection from moisture and provides long-term stability and reliability.
APPLICATIONS:
- Silo, tanks and hoppers
- Suspended silos, tanks and hoppers
- Railroad scales
- Weighbridges
Specification
Rated load |
50K lbs
100K lbs
|
Combined error |
± 0,05 % of rated output
|
Overload, safe |
150% of RL
|
Rated output |
2 mV/V ± 0,1%
3 mV/V ± 0,1%
|
Resistance |
input: 350 ± 3,5 Ω
output: 350 ± 3,5 Ω
|
Sensor material |
stainless steel
|
Protection class |
IP 68
|
Operating temperature |
-53...+93°C
|
Files
Data sheet | |
Load Cells - Product Overview |