Loading

1002

Code: 1002
  • low profile single-point load cell
  • capacities: 0.5...20 kg for 350 ohm, 5...30 kg for 1000 ohm
  • aluminum construction
  • single-point 200 x 200 mm platform
  • IP66 protection
Description

The Model 1002 is a very small, low capacity, aluminum single-point load cell, equally suitable for simple weighing scales or for industrial measurement and medical applications.
The Model 1002 has the advantage of very small size.
It is, therefore, both versatile and easy to use in a wide variety of industrial measurement applications.
Optional 1000-ohm strain gages are particularly suitable for connection to battery-powered equipment (designated Model 1002-K).
Typical applications include packing machines, filling machines, weaving machines, industrial process control, and low-force medical applications, as well as small-platform weighing.

Specification
Rated load
0,5 kg
1 kg
2 kg
3 kg
5 kg
8 kg
10 kg
15 kg
20 kg
30 kg
Combined error
± 0,1% of rated output
Overload, safe
150% of RL
Resistance
input: 350 ± 50 Ω
output: 350 ± 50 Ω
input: 1000 ± 50 Ω
output: 1000 ± 50 Ω
Rated output
0,5 mV/V
1,5 mV/V
Sensor material
aluminum
Protection class
IP 66
Operating temperature
-20...+70°C
Files
Data sheet
Load Cells - Product Overview