Loading

CPK-HF-28

Code: CPK-HF-28N
  • high-frequency limit level sensors
  • for reliable limit level sensing of various liquids, slurries and pastes
  • installation with the tubular extender in tanks, containers, sumps or funnels and containers
  • resistant to adhesion of viscous and adhering media (ketchups, yoghurts, spreads, syrups, creams, pastes, cleaning agents, etc.)
  • unique material type resolution function „medium window“ (the sensor is sensitive only to the set medium and does not react to other substances
  • can replace vibration level sensors
  • adjustment with a magnetic pen or by means of a setting wire
  • universal design for all types of liquids
  • high stability at high sens
Description

The CPK-HF-28 high-frequency level sensor is designed for industrial use for limit sensing of liquid and paste media. The high-frequency level sensor may be a direct replacement for a vibrating level sensor, or for a capacitive level sensor in the case of more demanding applications. The media may be electrically conductive or non-conductive with any permittivity. The sensor can be installed in metal or plastic tanks, filling tanks, sumps, etc. The RG variant can be installed using the TN-28 extension tube or in a similar way. The sensor works on the high frequency band, enabling reliable detection of the level of media, and eliminating deposits or foam on the electrode. The sensor suppresses the influence of deposits of viscous media (ketchup, yoghurt, mayonnaise, patés, syrups, jams, creams, soap) as well as electrically conductive adhesive products (detergents, lyes, chemicals).
The sensor can be set up by applying a magnetic pen to sensitive spots (variants CPK-HF-28_-_-_-P/PD-_) or using the programming wire (variant CPK-HF-28_-_-_-PD-_). For remote parametrization using the programmable wire, the special SSU-1212-AD unit is used.

The sensors can be set to perform:

  • simple sensing of the presence of the medium (medium/air)
  • distinction of the interface between two media (medium/medium), e.g. water/oil
  • selective distinction of a specific medium (medium window function), the function can distinguish e.g. oil from water and air, or detect only beer foam and ignore beer and air, etc.

The sensor is made from a stainless steel housing at one end terminated by a sensing electrode, and terminated at the other end and by an enclosure with a status indicator, control elements, and electrical connection. The setting elements are on the sides of the sensor. The sensors are manufactured for use in non-explosive areas only.

Specification
Output type
PNP
Electrical connection
cable gland
Process connection
G 3/4
3/4 NPT
Power supply
7...34V DC
Probe diameter
Ø28 mm
Operating temperature
-40...+80°C
Protection class
IP 68
Case material
stainless steel