Description
The hydrostatic probe LMK 458H has been developed for measuring level in service and storage tanks and is as a consequence certificated for shipbuilding and offshore applications.
A permissible operating temperature of up to 85°C and the possibility to use the device in intrinsic safe areas enable to measure the pressure of various fluids under extreme conditions. The basis for the LMK 458H is a capacitive ceramic sensor element, which offers a high over-load resistance and medium compatibility.
Specification
| Measurement range |
0...0,6 mH2O up to 0...200 mH2O
|
| Output type |
4...20 mA, 2-wire
HART
|
| Electrical connection |
cable outlet with TPE-U cable
|
| Probe diameter |
Ø39,5 mm
|
| Diaphragm |
ceramics Al2O3 (99.9 %)
ceramics Al2O3 (96 %)
|
| Power supply |
12...36V DC
14…28V DC
|
| Accuracy |
±0,1%
±0,2%
|
| Medium temperature |
-25...+85°C
|
| Protection class |
IP 68
|
| Case material |
stainless steel
CuNi10Fe1Mn
|
| Case dimensions |
Ø39,5 x 173 mm
|
Files
| Data sheet | |
| Manual | |
| Manual IS version | |
| Declaration of conformity |