Description
The stainless steel probe LMK 382 has been designed for continous level measurement in waste water, waste and higher viscosity media.
Basic element is a robust and high overpressure capable capacitive ceramic sensor e.g. for low levels easily.
Specification
| Measurement range |
0...0,4 mH2O up to 0...200 mH2O
|
| Output type |
4...20 mA, 2-wire
0...10V, 3-wire
|
| Electrical connection |
cable outlet with PVC cable
cable outlet with PUR cable
cable outlet with FEP cable
cable outlet with TPE-U cable
|
| Probe diameter |
Ø39,5 mm
|
| Diaphragm |
ceramics Al2O3 (99.9 %)
ceramics Al2O3 (96 %)
|
| Power supply |
9…32V DC
14…28V DC
12,5…32V DC
|
| Accuracy |
±0,35%
±0,25%
|
| Medium temperature |
-20...+125°C
|
| Protection class |
IP 68
|
| Case material |
stainless steel
|
| Case dimensions |
Ø39,5 x 124 mm
|
Files
| Data sheet | |
| Manual | |
| Manual IS version | |
| Declaration of conformity |