Description
The separable stainless steel probe CPA-K-358 has been designed for level measurement in waste water, waste and higher viscosity media. Basic element is a capacitive ceramic sensor.
In order to facilitate stock-keeping and maintenance the transmitter head is plugged to the cable assembly with a connector and can be changed easily.
Specification
| Measurement range |
0...0,4 mH2O up to 0...100 mH2O
|
| Output type |
4...20 mA, 2-wire
0...10V, 3-wire
|
| Electrical connection |
cable outlet with PVC cable
cable outlet with PUR cable
cable outlet with FEP cable
cable outlet with TPE-U cable
|
| Probe diameter |
Ø39,5 mm
|
| Diaphragm |
ceramics Al2O3 (99.9 %)
ceramics Al2O3 (96 %)
|
| Power supply |
9…32V DC
14…28V DC
12,5…32V DC
|
| Accuracy |
±0,35%
±0,25%
|
| Medium temperature |
-20...+125°C
|
| Protection class |
IP 68
|
| Case material |
stainless steel
|
| Case dimensions |
Ø39,5 x 178,5 mm
|
Files
| Data sheet | |
| Manual |